Water
Safe water where the grid and the supply chain do not reach: desalination priced honestly, leaks located, wells witnessed, and disinfection that needs no chemical deliveries.
Paper · DOI 10.5281/zenodo.24108541
A Solar-Powered Ultraviolet-C LED Disinfection Unit for a Village Standpipe, Sized on the Minimum Delivered Dose in Turbid Water
The problem. Safe drinking water where chlorine supply chains fail — disinfection with no consumable chemical, generated on site from sunlight, with its limits (no residual protection after treatment) stated plainly.
The result. Sizing a baffled serpentine UV-C reactor on its 5th-percentile (minimum-class) dose rather than its mean dose — the mean must be set at 2.01 times the required fluence, and a mean-sized reactor would pass 54.7% of its flow under-treated — a solar standpipe unit guaranteeing a 4-log bacteria-class dose at 5 NTU and 20 L/min needs 151.5 W of LED power, a 345 Wp array and a 404 Wh battery, while the virus-class dose costs ten times as much on every figure.
Paper · DOI 10.5281/zenodo.24108543
Locating Distribution Leaks by Pressure-Transient Timing on a Network of Low-Cost Loggers: A Method for Plastic-Pipe Networks Where Acoustic Correlation Fails
The problem. Cities and towns lose a large share of treated drinking water through leaks before it reaches a tap, worst where utilities are poorest, and the standard acoustic locating method fails on the plastic pipe those networks are made of.
The result. Timing low-frequency pressure transients between $30-class loggers at 250 m spacing and 10 Hz sampling locates leaks in polyethylene pipe to a standard error of 6.7 m — 4.07 times tighter than in ductile iron, because the plastic wave is slower — with a detection floor of a 3.08 mm equivalent hole at 250 m, covering a 5,000-person town's 50 km of mains with 201 loggers for $6,030 in hardware.
Paper · DOI 10.5281/zenodo.24108571
A Batch Reverse-Osmosis Cycle Whose Pressure Follows the Osmotic Curve: First-Principles Energy Accounting and a Sized Village Unit
The problem. Coastal and island communities with weak grids cannot afford the electricity that conventional seawater desalination demands, so abundant seawater stays undrinkable where power is scarcest.
The result. A batch seawater reverse-osmosis cycle whose feed pressure ramps to follow the osmotic curve of the concentrating charge uses 1.814 kWh per cubic metre of permeate at 35 g/L and 50% recovery — 21.7% less than a conventional continuous plant with isobaric energy recovery computed the same way (2.318 kWh/m3) — and needs no energy-recovery device.
Paper · DOI 10.5281/zenodo.24108587
A Psychrometric Bound on Atmospheric Water Harvesting: Where Air-Derived Water Can Work, Where It Cannot, and One Design That Respects the Bound
The problem. Households in drought regions are sold machines claiming litres of water from air at household power, with yields quoted without the temperature and humidity at which they were obtained; in the dry air where the need is greatest, those yields collapse to a fraction of a litre per kilowatt-hour.
The result. Below roughly 42% relative humidity, extracting water from air costs more energy — even for a thermodynamically perfect machine — than desalinating seawater and trucking it 100 km, and a realistic condensation machine beats a 500-km delivered supply only above 73.6–87.3% relative humidity, so harvesting is a humid-air, long-haul niche and not a water supply for arid air.
Paper · DOI 10.5281/zenodo.24108770
A Rain-Ingress Witness for Hand-Dug Wells and Boreholes: Mixing-Derived Detection Floors, Alarm Behaviour and Lead Time from a Low-Cost Conductivity and Temperature Logger
The problem. After storms, surface water enters wells and people drink the contamination before anyone knows; the witness flags the ingress before the next draw.
The result. A mixing-derived alarm (EC drop of 4 µS/cm sustained 2 h) on a low-cost conductivity/temperature logger fires at 0.81% ingress — 19.0 L in a 2,356 L hand-dug well, 2.85 L in a 353 L borehole — with no false alarms in the modelled 89-day baseline and 2.61 h of warning before the end of a 5%-in-6-h design storm.
Paper · DOI 10.5281/zenodo.24108806
A Village Chlorination System with No Chemical Supply Chain: Electrolytic Hypochlorite from Salt, Water and Sunlight, Sized End-to-End from Electrochemistry and Chlorine Decay
The problem. Disinfection that stops when a chlorine delivery does not come — a village water supply left unprotected because its disinfectant depends on a supply chain.
The result. A complete first-principles sizing shows a 10.0 m³/day village supply can be disinfected with no chlorine deliveries — a tank dose of 1.185 mg/L, decay-corrected production of 13.65 g of chlorine per day at 4.652 kWh/kg, requiring 63.5 Wh/day and 45.0 g of salt per day, with storage decay at 30 °C forcing a production oversize factor of 1.152.
Paper · DOI 10.5281/zenodo.24108834
A Batch Solar Water Pasteurizer with Counterflow Heat Recovery: Lethality Priced from Thermal Death Kinetics and Daily Output Sized from Insolation
The problem. Boiling drinking water where fuel is scarce costs scarce fuel or gathering time and fills homes with smoke, while the pathogens that matter are killed well below boiling if the water is held at temperature and its heat is recovered.
The result. With counterflow heat recovery at effectiveness 0.70, the batch cycle pasteurizes at 65 °C with a 10 min hold — a hold set by the enteric-virus class, which needs 9.0 min at 65 °C for a 6-log reduction while a 1 min hold gives it only 0.67 log — for a net 50.23 kJ per litre, 0.160 of the sensible heat of boiling, so one square metre of collector treats 179.2 litres per day and a 200 L/day school unit needs 1.12 m² of collector with a 50.0 L batch tank in 4 cycles per day.
Paper · DOI 10.5281/zenodo.24108838
Rainwater Tank Sizing by Stochastic Reliability Simulation: Storage–Reliability Design Curves for a Semi-Arid and a Monsoon Climate
The problem. A rainwater tank is often a poor household's largest single purchase, and folklore sizing leaves it too small to bridge the dry season or too large to ever fill.
The result. Storage–reliability curves from a Markov-generator daily balance (249 simulated years per configuration) give explicit tank sizes for 90% and 98% reliability in semi-arid (520.7 mm/yr) and monsoon (1511.5 mm/yr) climates; the semi-arid 40 m² / 50 L/day case is supply-limited (ratio 0.91) so no tank reaches 98%, the one-month rule delivers only 50.1–84.8%, and the largest dry-spell rule delivers 87.7–100.0% at up to four times the necessary size.
Paper · DOI 10.5281/zenodo.24109063
Freeze Desalination Priced Honestly: Full Accounting of Washing, Brine Entrainment and Refrigeration for Natural and Refrigerated Freezing of Seawater
The problem. Energy-poor cold coastal communities live beside undrinkable seawater and free winter cold, and are sold freezing as a cheap desalination route on the strength of its latent heat alone, without the washing, entrainment and refrigeration costs that decide whether it actually works for them.
The result. With brine entrainment and washing charged, refrigerated freeze desalination of seawater costs 53.2 kWh/m3 at COP 2.5 (17.7 times reverse osmosis at 3.0 kWh/m3), while natural tray freezing at −10 °C in light wind yields a net 13.25 L/m2/day — 75.5 m2 per m3/day — so the latent-heat advantage survives only where the cold is free.
Paper · DOI 10.5281/zenodo.24109065
Intermittent Water Supply: The Intrusion Volume per Outage Computed from First Principles, and a Household Break-Tank Design That Defeats It
The problem. Hundreds of millions of people receive piped water only a few hours a day, and when pressure dies the network draws contaminated soil water in through the same leaks that lose treated water when pressure is up, so the network doses itself between the treatment works and the tap.
The result. For the stated 10 km reference network, each supply outage draws 1.49 m³ of soil water in through the network's own leaks (2.98 m³/day, 0.30% of daily supply), and a nominal 75 L household break tank with a 40 mm air-gap inlet bridges the two-window supply pattern at 50 L/day essential demand with a chlorine re-dose interval of 6.0 days at 20 °C falling to 2.0 days at 35 °C.
Paper · DOI 10.5281/zenodo.24109067
The Electrodialysis–Reverse Osmosis Crossover for Brackish Groundwater: A First-Principles Energy Derivation and a Sized Village Electrodialysis Unit
The problem. Millions drink from brackish boreholes that are too salty for comfort yet too dilute for seawater-style reverse-osmosis habits, and the choice between electrodialysis and reverse osmosis for such water is usually made by habit rather than by calculation.
The result. Derived from stated first principles under one accounting rule, electrodialysis and reverse osmosis specific energies for brackish desalination to 0.5 g/L cross at a feed salinity of 6.90 g/L — ED lower below, RO lower above, and no crossover up to 20 g/L if RO brine energy recovery is removed — and a village ED unit for a 2.5 g/L borehole producing 5 m³/day needs 26 cell pairs at 10.50 A and 7.49 V, uses 1.82 kWh/day (0.41 kWp of photovoltaics at the stated yield), and is limited by gypsum solubility to a maximum recovery of 0.813.
Paper · DOI 10.5281/zenodo.24109077
The Virus-Removal Ceiling of Gravity Ceramic and "Nano" Point-of-Use Filters: A Sieving and Adsorption Accounting
The problem. Households in virus-risk settings spend money and trust on viral safety these filters cannot provide, and a filter believed to remove viruses displaces boiling and chlorination that actually inactivate them.
The result. At their stated pore ratings of 0.2–0.9 µm, gravity ceramic and "nano" point-of-use filters have a sieving ceiling of at most 0.66 log10 virus removal (0.000 log10 for 20–30 nm viruses), so marketed 4–6 log virus claims understate viral passage by factors of 2,163 to 216,290, while the same model confirms cyst removal at the 12-log cap and strong bacterial removal at finer ratings.
Paper · DOI 10.5281/zenodo.24109216
A Subsurface-Flow Constructed Wetland for a Household Cluster's Greywater, Sized by Removal Kinetics: The Bed Area, the Pathogen Reduction, and the Arid Salt Budget That Decide Its Reuse Class
The problem. Most of a household's water is greywater used once and discarded in places that cannot afford to use water twice, and most reuse guidance is a drawing rather than a computation, so it cannot say what its effluent may safely be used for or whether its salt slowly poisons the soil.
The result. A 12.92 m² subsurface-flow wetland sized by first-order kinetics for a 10-person cluster's 600 L/day of greywater reaches its BOD target and delivers a 1.68 log E. coli reduction sufficient for restricted irrigation, but it is 20.72 times the unrestricted-irrigation limit and barred from unrestricted reuse by a virus ceiling, while its arid salt loop closes for tolerant and moderately sensitive crops (leaching 2.96% and 10.12%) but not for sensitive crops (29.82%).
Paper · DOI 10.5281/zenodo.24109218
The Reservoir Is the Sand: Extractable-Storage Accounting, Evaporation Suppression and Worked Sizing for a Sand Dam on a Seasonal River
The problem. Villages beside seasonal rivers watch a year's water pass in a few weeks of flow, then face months with a dry bed; a sand dam keeps some of that flow in the sand, but rule-of-thumb sizing never states whether it holds enough extractable water to bridge the dry season.
The result. Priced as a porous reservoir, a sand dam for 400 people at 20 L/day through a 180-day dry season needs 1,440 m³ of extractable water in a corrected sand body 147.4 m × 20 m × 2.0 m (5,895.8 m³ at specific yield 0.25), and storing in sand saves 3,350.6 m³ of evaporation against an open reservoir of the same plan area (34.0 m³ lost through a 0.30 m dry crust against 2,907.5 m³ open), equivalent to 359.2 days of village supply.
Paper · DOI 10.5281/zenodo.24109228
Defluoridation Priced at the Working Point: Activated Alumina Costed from Its Isotherm Against Nalgonda Precipitation Costed from Its Dose, and a 1,000 L/day Village Kiosk Sized on the Winner
The problem. Across the fluoride belts the only water is the well, its groundwater carries 2–10 mg/L of fluoride that cripples teeth and bones, and the standard treatment advice names a medium or a dosing method without pricing either at the chemistry of the water actually in the ground.
The result. Priced under one accounting rule with isotherm capacity at the working point and regeneration charged in full, adsorption on activated alumina costs USD 0.295, 0.864 and 1.735 per m³ at feeds of 2, 5 and 10 mg/L while Nalgonda precipitation costs USD 0.057, 0.229 and 0.516 per m³ but breaches the stated 0.2 mg/L residual-aluminium limit at the two higher feeds (0.389 and 0.875 mg/L), so precipitation wins only at 2 mg/L, adsorption wins at 5 and 10 mg/L, running unadjusted at pH 7.5 destroys 49.3–65.4% of alumina capacity, and a 1,000 L/day kiosk at the 5 mg/L design feed runs on two alternating 11 kg beds at USD 0.864 per m³ with 4.23 operator hours per week.
Paper · DOI 10.5281/zenodo.24109230
Designing a Fog Collector Instead of Copying One: Droplet-Capture Physics, Shade-Coefficient Optimisation and an Honest Seasonal Yield for an Arid Coastal Climate
The problem. Settlements on arid coasts where rain is rare live under fog that carries renewable water over them daily, but collectors are copied rather than designed, so mesh, geometry and expected yield are guesses instead of computed choices matched to the local fog.
The result. Computing droplet capture from the Stokes number across a stated fog spectrum selects a 0.3 mm fibre at shade coefficient 0.50 (total collection efficiency 0.3213), and a 40 m² panel of that design yields 111,041 L per season in the central arid-coastal fog class — 21.77 times the 5,100 L per year of a 40 m² rain roof at the same site.
Paper · DOI 10.5281/zenodo.24109346
Forward Osmosis Priced Honestly: A Regeneration Bound That Closes the Seawater Claim, and the Fertilizer-Draw Irrigation Design That Survives It
The problem. Irrigation water and desalination cost are both scarce in dry agricultural regions, and forward osmosis is marketed there as low-energy desalination although the draw regeneration that performs the actual separation is left out of the price.
The result. Regenerating any forward-osmosis draw costs more minimum work than desalinating the feed directly (bound 1.53 vs 1.06 kWh/m³ for seawater at 0.50 recovery; a stated NaCl draw totals 6.09 vs 3.04 kWh/m³ for RO at equal efficiency, and a thermolytic draw flips only if 56.49 kWh/m³ of heat at 60 °C is free), while a fertilizer-draw unit that skips regeneration entirely — 1,484 m² of membrane delivering 50 m³/day from 2.0 g/L brackish groundwater — over-delivers nitrogen 18.7–65.6× at full irrigation rate but, spread nitrogen-matched, is the complete fertilizer source for 32.8 ha of medium-demand crops while supplying 3.1% of their water.