Shelter — houses, buildings, and household systems raised from the materials at hand and sized by honest arithmetic.
Housing & Shelter
Waste-Heat Recovery for a Small Intermittent Brick Kiln: Air Preheat and Brick Drying, with Costs, Failure Modes and the Cases Where It Is Not Worth Building
This blueprint specifies a waste-heat recovery system for one stated case: a small intermittent brick kiln firing 10,000 bricks per batch on a 48-hour firing schedule, as defined in the source paper. The system has three parts, in the order the flue gas meets them: 1.
Design paper · DOI 10.5281/zenodo.24108732 · Blueprint package · DOI 10.5281/zenodo.24110739
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Straw and Rice-Husk Fibre Insulation Panel: Specification and Computed Thermal, Moisture, Cost and Fire-Behaviour Envelope
This blueprint specifies a semi-rigid, non-loadbearing insulation panel made from agricultural residues: 68% wheat straw fibre, 22% ground rice husk, 6% starch binder and 4% borate treatment by dry mass, at a nominal density of 110 kg per cubic metre. Fibres lie mainly in the plane of the board and trap still air, which provides the insulation.
Design paper · DOI 10.5281/zenodo.24108637 · Blueprint package · DOI 10.5281/zenodo.24110808
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Lashed-Plus-Bolted Bamboo–Timber Joint for Low-Rise Housing: Connector Design and a Computed Shear, Pull-Out and Slip Budget Across Culm Diameter and Moisture
This blueprint specifies one joint connecting the end region of one bamboo culm (rafter, purlin or joist end) to a timber ledger or tongue 40 mm thick. Two cheap elements share the work.
Design paper · DOI 10.5281/zenodo.24108639 · Blueprint package · DOI 10.5281/zenodo.24110876
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Confined-Masonry Wall System for One-Storey Stabilised-Earth Housing: Tie-Column and Ring-Beam Layout with a Computed Seismic Shear and Stability Budget
This blueprint specifies a complete confined-masonry wall system for a one-storey house in stabilised-earth block. Masonry panels are confined on all four sides: reinforced-concrete tie-columns stitch corners, wall ends, intersections and long walls, and a continuous reinforced-concrete ring beam ties the tops of all walls into a single line.
Design paper · DOI 10.5281/zenodo.24109150 · Blueprint package · DOI 10.5281/zenodo.24110852
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Universal 6% Equal-Split Lime-Cement Formulation for Stabilised-Earth Wall Blocks: A Mix-Selection Computation Balancing Strength, Wet Durability, Embodied Energy and Cost
A single earth-block recipe — 94% soil, 3% cement, 3% lime — that works across soils from 15% to 40% clay. It serves block-machine makers and housing programs.
Design paper · DOI 10.5281/zenodo.24108442 · Blueprint package · DOI 10.5281/zenodo.24110647
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Porous Ceramic Evaporator Wall for a Single Room in Arid Housing: Computed Indoor Temperature Reduction, Water Use per Degree, and the Humidity Ceiling
This blueprint specifies a direct evaporative cooling wall for one room in arid housing. Outside air is drawn by a small fan through a wet, porous ceramic wall into the room.
Design paper · DOI 10.5281/zenodo.24108880 · Blueprint package · DOI 10.5281/zenodo.24110591
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Passive Radiative-Cooling Roof Assembly for Heat-Wave Housing: Computed Cooling Budget and Price per Degree of Indoor Temperature Reduction
This blueprint specifies a passive roof for a single-storey room of 4 m by 4 m (floor and roof area 16 m², volume 43.2 m³). The roof rejects sunlight by high solar reflectance and radiates heat to the sky through the 8–13 micrometre atmospheric window by high long-wave emissivity.
Design paper · DOI 10.5281/zenodo.24108520 · Blueprint package · DOI 10.5281/zenodo.24110475
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Continuous Load-Path Strap-and-Anchor Roof Tie-Down Assembly for Low-Cost Housing: A Computed Uplift Budget and Its Limit Wind Speed
A continuous strap-and-anchor assembly that keeps the roof-to-ground load path unbroken in storm winds. It serves construction-hardware manufacturers and, secondarily, insurers' mitigation suppliers.
Design paper · DOI 10.5281/zenodo.24109101 · Blueprint package · DOI 10.5281/zenodo.24110662
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
What Actually Saves the House: A Priced Cost-Effectiveness Ranking of Ember-Attack Home Hardening, and the Cheapest Bundle That Buys a Stated Survival Probability
Most homes lost in wildland-urban interface fires are ignited by wind-blown embers, not by a wall of flame. This blueprint specifies, in ranked installation order, the six-measure hardening package for the source reference house — single-storey, 150 m2, replacement value US$450,000, Class A roof already fitted — exposed to a severe ember event with no fire-service suppression, in which the unhardened ignition probability is 0.40 and survival is 0.600.
Design paper · DOI 10.5281/zenodo.24108438 · Blueprint package · DOI 10.5281/zenodo.24111259
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Heat-Wave Survival Room: The Integrated Design, Computed Cooling Budget and Cost per Protected Person for One Cooled Room per Dwelling
A room-by-room envelope package that keeps one room survivable through a heat wave where whole-home cooling is unaffordable. It serves municipalities, landlords, and heat-action programs working through building suppliers.
Design paper · DOI 10.5281/zenodo.24108469 · Blueprint package · DOI 10.5281/zenodo.24111209
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Lime and Ash: What a Wood-Ash Pozzolan Mortar Can and Cannot Do
A mortar of lime and rice husk ash at 1:2, moist-cured, honestly claimed at M2.5 (2.96 MPa at 28 days in simulation), and not used below ground or in standing water. Wood-ash-only and ash-clay mixes in the source paper do not meet their claimed strengths and are not specified here.
Design paper · DOI 10.5281/zenodo.24115095 · Blueprint package · DOI 10.5281/zenodo.24119115
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
How Far Can a Bamboo Culm Span? Bending Strength and Deflection Bounds for Single and Bundled Culms
Bamboo culm beams, single or bundled, spanning only within the deflection-governed bounds in the source paper for the stated loads. Bamboo culms are used as rafters, purlins, and joists in a great deal of the world's building, and the question a builder actually asks — how far can this culm reach before it is overstressed or sags too much — is usually answered by tradition rather than by number.
Design paper · DOI 10.5281/zenodo.24115123 · Blueprint package · DOI 10.5281/zenodo.24119126
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
The Bamboo Column Bound: Safe Axial Load by Culm Diameter, Wall Thickness, and Node Spacing
A bamboo culm used as a post is usually sized by habit: a thick culm for a heavy roof, a thin one for a light wall, with no number attached to either choice. This paper replaces habit with a computed bound.
Design paper · DOI 10.5281/zenodo.24115142 · Blueprint package · DOI 10.5281/zenodo.24119143
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Bolt Through a Bamboo Culm Does Not Use the Culm's Strength: Splitting and Bearing Bounds at Pinned Joints, and a Lashing Rule That Does
A bolted bamboo joint detailed so bearing and splitting at the pin stay within the bounds computed in the source paper. Bolting is the connection method a builder trained on timber or steel reaches for first, and in bamboo it is applied with an expectation this paper tests and disproves by arithmetic: that a bolted joint transfers something like the culm's own strength.
Design paper · DOI 10.5281/zenodo.24115172 · Blueprint package · DOI 10.5281/zenodo.24119156
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
The Dry-Stone Retaining Wall Bound: Batter, Base Thickness, and the Height a Vertical Face Cannot Reach
A dry-stone retaining wall built with the batter and base thickness given in the source paper for its height, not as a vertical face beyond the computed reach. Dry-stone retaining walls are traditionally built with a batter — the face leaning back into the hill — and traditionally defended by assertion.
Design paper · DOI 10.5281/zenodo.24115205 · Blueprint package · DOI 10.5281/zenodo.24119168
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Foundation Width from the Ground Up: A Bearing Rule for Stone Strip Footings
A stone wall is heavy enough that its foundation is a calculation, not a detail, yet footing widths are still commonly chosen as the wall's thickness plus a hand's breadth, whatever the ground. This paper builds the width from the ground up.
Design paper · DOI 10.5281/zenodo.24115230 · Blueprint package · DOI 10.5281/zenodo.24119186
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
The Honest Load of a Green-Timber Lintel: Strength Loss and Creep in Unseasoned Wood
An unseasoned timber lintel loaded only to the reduced strength, with the creep allowance, computed in the source paper. Builders frequently install a lintel green — freshly sawn, still wet — and then load it with the wall it was meant to carry, while the only capacity figures at hand come from tables for seasoned timber.
Design paper · DOI 10.5281/zenodo.24115252 · Blueprint package · DOI 10.5281/zenodo.24119199
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Lashed, Pegged, or Notched: Computed Strengths for Timber Joints Without Metal, and a Selection Rule
Timber joints made by lashing, pegging or notching, each used only up to the computed strength and under the selection rule in the source paper. Timber can be joined without any metal at all, by lashing members together with rope, by driving wooden pegs through them, or by cutting one member to fit into a notch in the other.
Design paper · DOI 10.5281/zenodo.24115271 · Blueprint package · DOI 10.5281/zenodo.24119215
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
The Round-Log Beam Rule: Span from Diameter for Roof and Floor Loads
A round log used whole, without sawing, is one of the oldest beam forms available to a builder who has trees but no mill. This paper originates a sizing rule for such beams by computing, for a circular cross-section, both the span at which bending strength is exhausted and the span at which sag reaches a stated limit, for two stated load cases and three stated species classes.
Design paper · DOI 10.5281/zenodo.24115291 · Blueprint package · DOI 10.5281/zenodo.24119230
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Mud Brick and Stabilised Earth: Strength by Mix, and the Least Cement or Lime That Does the Work
Mud bricks, stabilised where needed with the least cement or lime that the source paper's mix strengths show to do the work. Earth dug on site is the cheapest wall material available in much of the world, and also the least predictable, because two soils that look alike can differ by a factor of two in strength and by far more once rain reaches them.
Design paper · DOI 10.5281/zenodo.24115317 · Blueprint package · DOI 10.5281/zenodo.24119243
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Scaffolds and Formwork from Poles: Safe Loads, Bracing, and the Bay Size That Holds
A scaffold and formwork system built from poles, with the bracing and bay size given in the source paper and loaded only to its computed safe loads. Where steel tube scaffolding is unavailable or unaffordable, scaffolds and formwork are built from timber poles lashed or nailed together, and they are usually sized by copying whatever stood last time.
Design paper · DOI 10.5281/zenodo.24115338 · Blueprint package · DOI 10.5281/zenodo.24119259
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Roof Trusses from Poles: Geometry and Member Sizes for Spans from Four to Eight Metres
A roof truss built from poles, with the geometry and member sizes given in the source paper for spans from four to eight metres. Where sawn timber is scarce or expensive, roof trusses are often built from round poles — and usually sized by copying whatever stood up last time.
Design paper · DOI 10.5281/zenodo.24115352 · Blueprint package · DOI 10.5281/zenodo.24119279
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Rammed Earth by Layers: Lift Thickness, Compaction Energy, and the Slenderness Bound
A rammed earth wall is built one shallow layer at a time, and its quality is decided by choices made hundreds of times a day: how thick each loose layer is spread, how much work is beaten into it, and how wet the soil is when the rammer falls. This paper originates a wall rule connecting those choices to the finished wall.
Design paper · DOI 10.5281/zenodo.24115370 · Blueprint package · DOI 10.5281/zenodo.24119294
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
How Thick Must a Rubble Stone Wall Be? A Stability Bound by Height and Mortar
A rubble stone wall built to the thickness given in the source paper's stability bound for its height and mortar. How thick a rubble stone wall must be is usually answered by habit: a fixed proportion of the height, the same for a mortared wall as for one laid dry.
Design paper · DOI 10.5281/zenodo.24115398 · Blueprint package · DOI 10.5281/zenodo.24119307
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Thatch Against Rain and Rot: Pitch, Thickness, and Service Life by Material and Climate
A thatched roof keeps a building dry by a division of labour inside the coat: the outer part may wet and dry with every storm, while an inner layer must stay dry for the life of the roof, because material that stays wet is material that rots. This paper originates a combined design rule that joins the two halves of that bargain in one calculation.
Design paper · DOI 10.5281/zenodo.24115440 · Blueprint package · DOI 10.5281/zenodo.24119327
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Counted, Not Placed for Symmetry: How Many Downpipes a Roof Actually Needs
Houses are routinely built with downpipes wherever the elevation looks balanced, and gutters overflow in extreme rain is then blamed on the gutter.
Design paper · DOI 10.5281/zenodo.24119002 · Blueprint package · DOI 10.5281/zenodo.24120185
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
The Drip Lands Further Out Than the Trench: Width, Wind, and Impact Energy at an Unguttered Eave
Buildings without gutters shed their roof water from the eave edge, and the standard remedy for the erosion and splashing that follow is a gravel-filled trench along the wall.
Design paper · DOI 10.5281/zenodo.24120019 · Blueprint package · DOI 10.5281/zenodo.24120192
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Covered Drying for Green Bricks: How Much Roof per Thousand Bricks Keeps Rain Losses Below Fuel Savings
This paper addresses green bricks ruined by rain during open-air drying in wet seasons.
Design paper · DOI 10.5281/zenodo.24119012 · Blueprint package · DOI 10.5281/zenodo.24120287
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Rice Husk in Fired Bricks: Why More Husk Is Not Always Better, and the Blend That Best Balances Strength, Weight and Cost
This paper addresses the common belief that adding ever more rice husk to a brick always improves it because the brick becomes lighter and cheaper.
Design paper · DOI 10.5281/zenodo.24119069 · Blueprint package · DOI 10.5281/zenodo.24120312
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Washing Clay to Prevent Efflorescence: The Number of Wash Cycles That Brings Soluble Salt Below a Visible-Bloom Threshold
This paper addresses white salt bloom appearing on fired bricks and pots made from clay dug near saline ground, spoiling their appearance and weakening mortar bond.
Design paper · DOI 10.5281/zenodo.24119109 · Blueprint package · DOI 10.5281/zenodo.24120365
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Setter Spacing for Flat Roof Tiles: The Support Interval That Keeps Firing Warpage Within a Stated Tolerance
This paper addresses flat clay roof tiles that warp during firing because they are supported too far apart while soft at peak temperature.
Design paper · DOI 10.5281/zenodo.24119166 · Blueprint package · DOI 10.5281/zenodo.24120397
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Span Limit for Self-Supporting Brick Kiln Vaults: The Width a Catenary Arch of Fired Brick Can Cover Without Steel
This paper addresses kiln builders who want a permanent brick vault roof instead of a rebuilt temporary crown, but have no rule for how wide such a vault can safely span.
Design paper · DOI 10.5281/zenodo.24119182 · Blueprint package · DOI 10.5281/zenodo.24120404
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Bed Height for Older Sleepers: The Seat-Height Rule That Minimises Sit-to-Stand Effort, and the Fall Energy Cost of Exceeding It
Bed height is usually set by furniture fashion — deep mattresses on high frames — but for an older sleeper the height of the bed's top surface decides both how hard it is to stand up in the morning and how far there is to fall at night.
Design paper · DOI 10.5281/zenodo.24119402 · Blueprint package · DOI 10.5281/zenodo.24120531
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Blackout Is a Gap Problem: Light at the Eye from Blind Edge Leakage as a Function of Gap Width, and the Overlap That Replaces Expensive Fabric
Expensive blackout fabric is specified by its transmittance, but the light that reaches a sleeper's eye in a real installation is dominated by the gaps at the edges, not by the fabric.
Design paper · DOI 10.5281/zenodo.24119435 · Blueprint package · DOI 10.5281/zenodo.24120539
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
The Closed Bedroom Door: Overnight Carbon Dioxide Accumulation for One and Two Sleepers, and the Door Gap or Vent Area That Holds It Below 1000 ppm
Bedroom doors are closed at night for quiet and privacy, and the air inside a closed room is exchanged only slowly.
Design paper · DOI 10.5281/zenodo.24119598 · Blueprint package · DOI 10.5281/zenodo.24120560
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Pillow-Loft Rule from Neck Geometry: Compressed Loft as a Function of Shoulder Width, Head Mass, and Fill Stiffness for Side and Back Sleeping
Pillows are sold by fill and by adjectives, but the quantity the neck experiences is the compressed loft under the head at three in the morning.
Design paper · DOI 10.5281/zenodo.24119641 · Blueprint package · DOI 10.5281/zenodo.24120574
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
What a Sleeping Bag Rating Actually Buys: Insulation Thickness Required per Degree Below Freezing, and the Cost of the Mattress Pad the Rating Assumes
Sleeping bags carry comfort ratings in degrees, but the physical content of a rating is an insulation resistance, and the insulation a camper must carry grows linearly as the temperature falls.
Design paper · DOI 10.5281/zenodo.24119650 · Blueprint package · DOI 10.5281/zenodo.24120580
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
How Far Apart Can Snap Traps Sit? A Wall-Coverage Rule for the House Mouse in Kitchens and Store Rooms
Households are usually told to place mouse traps a short distance apart, but no spacing is ever derived.
Design paper · DOI 10.5281/zenodo.24121534 · Blueprint package · DOI 10.5281/zenodo.24122051
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Twelve-Millimetre Mesh Does Not Exclude Mice: A Passage-Probability Bound for Household Exclusion Work
Hardware cloth of 12 mm (half-inch) aperture is sold and fitted as rodent proofing, including against mice.
Design paper · DOI 10.5281/zenodo.24121624 · Blueprint package · DOI 10.5281/zenodo.24122058
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Stations Around a House Perimeter: Termite Interception Probability as a Function of Spacing
Bait stations for subterranean termites work only if a colony's galleries intersect a station, so the design variable is spacing around the building.
Design paper · DOI 10.5281/zenodo.24121651 · Blueprint package · DOI 10.5281/zenodo.24122076
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Deadbolt Throw Length: How Much Engagement Depth a Longer Bolt Actually Buys Against Frame Splitting
A deadbolt is sold by its throw, the distance the bolt travels into the frame, yet what a household needs is resistance to the frame splitting around the strike. This study models that resistance from stated assumptions: a steel bolt of 11 mm by 20 mm section has a shear capacity near 61,600 N and never governs, while the timber frame around the strike pocket is modelled as failing at F = 700 + 330 e^0.8 newtons, where e is the engagement depth in millimetres after a 4 mm allowance for door gap and strike recess.
Design paper · DOI 10.5281/zenodo.24121578 · Blueprint package · DOI 10.5281/zenodo.24122156
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Fence Post Spacing Under Wind Load: The Widest Bay a Timber Post Can Carry Before Bending Governs
A solid garden fence is a sail, and its posts are the masts. This study computes post bending stress under a stated gust pressure of 0.55 kN per square metre on a 1.8 m solid fence, with each interior post carrying one bay and acting as a 125 mm square timber section of stated allowable bending stress 8 MPa.
Design paper · DOI 10.5281/zenodo.24121597 · Blueprint package · DOI 10.5281/zenodo.24122170
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Timber Gate Sag: Diagonal Brace Angle and the Widest Gate That Still Latches After Five Summers
A timber garden gate that sags drops at its latch edge until the latch misses its keep, at which point the gate stops performing any security function at all. This study models sag from stated assumptions: an unbraced ledged gate drops 4.5 W^3 millimetres at width W metres after five seasons, a correctly fitted diagonal brace removes a fraction of that drop peaking at a brace angle of 45 degrees, and a latch tolerates 10 mm of drop.
Design paper · DOI 10.5281/zenodo.24121606 · Blueprint package · DOI 10.5281/zenodo.24122182
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Sliding Door Security Bars: The Dowel Diameter at Which a Timber Bar Stops Buckling Under a Forcing Load
A length of timber dropped into the track of a sliding patio door is among the cheapest security devices sold, and among the least specified: dowels are bought by eye, in diameters that vary by a factor of two. This study computes the buckling load of a 0.9 m pine dowel from the Euler relation with a stated elastic modulus of 9 GPa, and compares it with a stated forcing load of 2,600 N at which the door's rollers and track begin to deform.
Design paper · DOI 10.5281/zenodo.24121699 · Blueprint package · DOI 10.5281/zenodo.24122194
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Strike Plate Screws: The Length at Which a Door Strike Stops Being the Weakest Part of the Lock
Many deadbolts are defeated not at the bolt but at the strike plate, whose short screws bite only into the thin frame facing rather than the structural timber behind it.
Design paper · DOI 10.5281/zenodo.24121725 · Blueprint package · DOI 10.5281/zenodo.24122202
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Window Sash Lock Spacing: How Many Locks a Wide Window Needs Before Prying Flexes the Rail Open
A wide sliding or casement window fitted with a single central lock can be opened by prying at a corner, flexing the meeting rail until the latch clears its keeper, without breaking anything. This study models the rail as a beam from stated values: a 700 N pry, an aluminium rail of elastic modulus 69 GPa and second moment of area 7.5e-9 m^4, and a 6 mm flex at which the latch disengages.
Design paper · DOI 10.5281/zenodo.24121748 · Blueprint package · DOI 10.5281/zenodo.24122242
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Density-Capped Confinement Vessel: Sizing a Magnetic Bottle Whose Operating Point Sits Below the Aldred Density by Construction
The device is a toroidal magnetic confinement vessel, scanned over minor radius, operating a deuterium-tritium plasma at fifteen kiloelectronvolts and a stated density of ten to the twentieth particles per cubic metre, derived from stated assumptions and computed throughout by the accompanying script. The stated plasma pressure is 480.78 MPa, balanced by a field of 34.76 T, and the plasma mass density is a fraction 1.7e-25 of the Aldred Limit density, settling by arithmetic that gravitational shear ceilings cannot bear on a device of this class.
Design paper · DOI 10.5281/zenodo.24123333 · Blueprint package · DOI 10.5281/zenodo.24124350
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Shear-Capped Acceleration Stage: Gradient Limits for a Compact Linear Accelerator Set by the Aldred Shear Bound
The device is a ten-metre copper accelerating stage intended to add a stated energy increment to a charged-particle beam, with its gradient chosen not by optimism but by an explicit shear criterion applied to the electromagnetic stress in the cavity walls, derived from stated assumptions and computed throughout by the accompanying script. At 100 MV/m the field stress in the walls is 0.044 MPa and the ten-metre stage adds 1.0 GeV to a beam; at 50 MV/m it adds 0.5 GeV.
Design paper · DOI 10.5281/zenodo.24123377 · Blueprint package · DOI 10.5281/zenodo.24124376
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Electrostatic Torsion Lens for Charged-Particle Beam Shaping
The design presented in this paper is a electrostatic torsion lens intended for shaping ion beams for materials processing and instrument columns. Its operating principle is that a set of shaped electrostatic electrodes focuses a charged-particle beam, and an azimuthal electrode segment introduces a torsion-like twist to the focal field that is used to correct rotational aberration in the model.
Design paper · DOI 10.5281/zenodo.24133892 · Blueprint package · DOI 10.5281/zenodo.24134602
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Squeezed-Light Receiver for Torsion-Coupled Signal Channels
This paper designs an optical receiver whose readout noise is reduced below the ordinary shot-noise level by squeezed vacuum injection, and computes the benefit for a channel in which a torsion background modulates the phase of a probe beam.
Design paper · DOI 10.5281/zenodo.24138664 · Blueprint package · DOI 10.5281/zenodo.24138995
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Drag-Free Torsion Balance in Low Earth Orbit Searching for a Spin-Dependent Differential Acceleration
This paper presents a space mission design, computed from stated assumptions and not measured, built to measure one quantity: the differential acceleration attributed to a spin-dependent torsion coupling, for which the design case adopts 6.50e-15 metres per second squared. The instrument is a drag-free satellite carrying two torsion pendulums whose bobs are made of materials with opposite net nuclear spin polarisation, suspended on fused-silica fibres inside a common vacuum housing, with the whole payload slowly rotated so a genuine differential signal appears at the rotation frequency.
Design paper · DOI 10.5281/zenodo.24142387 · Blueprint package · DOI 10.5281/zenodo.24142970
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Inflatable Habitat Pressure Shell: Hoop Stress, Bladder Thickness, Mass and Comparison with a Rigid Shell
This paper presents a computed design for an inflatable pressure shell with a gas-retaining bladder, restraint layer and protective cover, sized from hoop stress at the operating pressure and compared on mass with a rigid aluminium shell of the same volume. The study is simulated, not measured.
Design paper · DOI 10.5281/zenodo.24145227 · Blueprint package · DOI 10.5281/zenodo.24146196
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Lava-Tube Habitat on the Moon: Overburden Shielding, Pressurised Volume and Thermal Stability
This paper presents a computed design for habitat modules placed inside a lunar lava tube, where metres of rock overburden supply radiation and micrometeoroid protection and the subsurface temperature is nearly constant. The study is simulated, not measured.
Design paper · DOI 10.5281/zenodo.24145238 · Blueprint package · DOI 10.5281/zenodo.24146204
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Loop-Heat-Pipe Radiator System for Habitat Heat Rejection: Radiating Area, Mass and Redundancy
This paper presents a computed design for a two-phase loop-heat-pipe system that carries habitat waste heat to external radiators, where it is radiated to space, with no pumped single-phase loop as the primary transport mechanism. The study is simulated, not measured.
Design paper · DOI 10.5281/zenodo.24145250 · Blueprint package · DOI 10.5281/zenodo.24146208
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Lunar Regolith Berm Shield for a Surface Habitat: Thickness, Excavated Mass and Thermal Damping
This paper presents a computed design for excavated lunar regolith piled over a rigid surface habitat, using in-situ bulk material rather than launched shielding mass. The study is simulated, not measured.
Design paper · DOI 10.5281/zenodo.24145262 · Blueprint package · DOI 10.5281/zenodo.24146214
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Water-Ice Dome Shield for a Mars Habitat: Thickness, In-Situ Mass, Dose Reduction and Sublimation Loss
This paper presents a computed design for a dome of frozen water built over a Mars habitat from in-situ ice, providing hydrogen-rich shielding while slowly losing mass by sublimation that must be replenished. The study is simulated, not measured.
Design paper · DOI 10.5281/zenodo.24145272 · Blueprint package · DOI 10.5281/zenodo.24146224
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Phase-Change Thermal Wall for a Lunar Habitat: Diurnal Storage Mass, Thickness and Temperature Stabilisation
This paper presents a computed design for a phase-change material wall that melts during the lunar day and freezes at night, absorbing and releasing heat at nearly constant temperature instead of relying entirely on active cooling. The study is simulated, not measured.
Design paper · DOI 10.5281/zenodo.24145287 · Blueprint package · DOI 10.5281/zenodo.24146232
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Rotating Ring Habitat for Artificial Gravity: Radius, Rotation Rate, Structure and Shielded Core
This paper presents a computed design for a rotating ring that provides artificial gravity at its rim, with a non-rotating or counter-rotating shielded core for radiation refuge, sized from centripetal acceleration, rotation rate and hoop tension. The study is simulated, not measured.
Design paper · DOI 10.5281/zenodo.24145301 · Blueprint package · DOI 10.5281/zenodo.24146240
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Variable-Emissivity Habitat Skin for Thermal Regulation: Emissivity Range, Area Saving and Control Power
This paper presents a computed design for an electrochromic skin whose infrared emissivity can be switched between low and high values, so the same panels retain heat in cold conditions and reject heat in warm conditions. The study is simulated, not measured.
Design paper · DOI 10.5281/zenodo.24145369 · Blueprint package · DOI 10.5281/zenodo.24146271
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Whipple Micrometeoroid Shield for a Habitat Pressure Shell: Bumper Spacing, Rear-Wall Thickness and Mass per Area
This paper presents a computed design for a Whipple shield in which a thin outer bumper shatters and disperses an incoming micrometeoroid before its debris cloud reaches the pressure wall, so protection comes from spacing and disruption rather than from a single thick plate. The study is simulated, not measured.
Design paper · DOI 10.5281/zenodo.24145413 · Blueprint package · DOI 10.5281/zenodo.24146300
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Zeolite Swing-Bed Carbon Dioxide Removal System: Bed Mass, Cycle Time, Regeneration Energy and Outlet Concentration
This paper presents a computed design for a twin zeolite adsorption system in which one bed adsorbs carbon dioxide from cabin air while the other is regenerated by heat and vacuum, providing continuous removal without expendable sorbent. The study is simulated, not measured.
Design paper · DOI 10.5281/zenodo.24145424 · Blueprint package · DOI 10.5281/zenodo.24146303
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A 61-Channel Coherently Combined Fibre Amplifier Array Sized by Phase Error and Combining Efficiency
This paper presents a computed design for a coherent beam combining array of 61 ytterbium-doped fibre amplifiers at 1064 nm, phased by a stochastic parallel gradient descent controller. The sizing follows from applying the relevant intensity, thermal, nonlinear and geometric bounds at a single stated operating point, with every number produced by a deposited computation.
Design paper · DOI 10.5281/zenodo.24155149 · Blueprint package · DOI 10.5281/zenodo.24155598
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Hollow-Core Fibre Beam Delivery Line Sized by Critical Power, Mode Loss and Bend Radius
This paper presents a computed design for a 5 m hollow-core anti-resonant fibre delivery line carrying millijoule femtosecond pulses from an amplifier to a processing head. The sizing follows from applying the relevant intensity, thermal, nonlinear and geometric bounds at a single stated operating point, with every number produced by a deposited computation.
Design paper · DOI 10.5281/zenodo.24155255 · Blueprint package · DOI 10.5281/zenodo.24155669
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Optical Phased Array Beam Steerer Sized by Emitter Pitch, Grating Lobes and Aperture Beamwidth
This paper presents a computed design for a silicon-photonic optical phased array of 1024 emitters steering a 1550 nm beam without moving parts. The sizing follows from applying the relevant intensity, thermal, nonlinear and geometric bounds at a single stated operating point, with every number produced by a deposited computation.
Design paper · DOI 10.5281/zenodo.24155342 · Blueprint package · DOI 10.5281/zenodo.24155751
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Treacy Grating-Pair Compressor for a 100 J Beam Sized by Dispersion, Separation and Grating Aperture
This paper presents a computed design for a four-grating Treacy compressor recompressing a 100 J, nanosecond-stretched pulse at 800 nm to the femtosecond range. The sizing follows from applying the relevant intensity, thermal, nonlinear and geometric bounds at a single stated operating point, with every number produced by a deposited computation.
Design paper · DOI 10.5281/zenodo.24155363 · Blueprint package · DOI 10.5281/zenodo.24155782
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Heavy-Ion Beam Inertial Fusion Plant: Accelerator Efficiency, Indirect-Drive Gain and Chamber Balance at One Hertz
This paper presents a complete, computed design study of a fusion power plant based on a heavy-ion inertial confinement chamber: a large chamber with a thick liquid wall, into which ion beams enter through ports in the flowing liquid. The fuel is deuterium tritium, releasing 17.6 MeV per reaction, of which 14.1 MeV leaves with the neutron and 3.5 MeV stays with the alpha particle.
Design paper · DOI 10.5281/zenodo.24159594 · Blueprint package · DOI 10.5281/zenodo.24160368
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Compact Spherical Tokamak Fusion Power Plant Sized by Energy Balance and Neutron Wall Loading
This paper presents a complete, computed design study of a fusion power plant based on a spherical tokamak: a tokamak compressed to low aspect ratio, so the plasma is nearly spherical and the centre column is slender. The fuel is deuterium tritium, releasing 17.6 MeV per reaction, of which 14.1 MeV leaves with the neutron and 3.5 MeV stays with the alpha particle.
Design paper · DOI 10.5281/zenodo.24159800 · Blueprint package · DOI 10.5281/zenodo.24160531
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Modulated Neutrino Beam for Through-Body Deep-Space Signalling: Interaction Rates in a Kilotonne Detector and Why the Required Source Power Rules the System Out
This paper presents a design study of a system whose operating principle is Modulated neutrino beam signalling detected by weak interactions in a large detector mass. The sizing is computed from stated assumptions, with every headline quantity produced by the deposited calculation script.
Design paper · DOI 10.5281/zenodo.24169162 · Blueprint package · DOI 10.5281/zenodo.24169671
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Thermochemical Lime Store for Seasonal Building Heat: Quicklime Mass, Hydration Heat, Reactor Volume and Summer-to-Winter Retention for Fifteen Hundred Usable Thermal Kilowatt-Hours
This paper sizes a thermochemical lime storage system for a housing block requiring summer heat to be carried into winter without standing losses. The duty calls for 1.5e+03 usable thermal kilowatt-hours delivered at a rated power of 80 kilowatts.
Design paper · DOI 10.5281/zenodo.24174173 · Blueprint package · DOI 10.5281/zenodo.24175512
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Ion-Beam Shepherd for a 140-Metre Asteroid: Beam Momentum Transfer Without Contact
This paper computes an ion-beam shepherd that directs a 1.1 N ion plume at a 140 m asteroid of mass 3,735,563,105 kg from a hovering spacecraft. Beam divergence and imperfect interception reduce the transferred force to 0.792 N, an acceleration of 2.12e-10 m per second squared.
Design paper · DOI 10.5281/zenodo.24180112 · Blueprint package · DOI 10.5281/zenodo.24181492
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Plasma-Beam Shepherd: Neutralised Particle-Beam Momentum Transfer to a 170-Metre Asteroid
This paper computes a plasma-beam shepherd that directs 260,000 W of beam power at 48,000 m per second toward a 170 m asteroid of mass 6,173,857,883 kg. Beam momentum flux reduced by a coupling fraction of 0.66 gives an effective force of 3.58 N and an acceleration of 5.79e-10 m per second squared.
Design paper · DOI 10.5281/zenodo.24180184 · Blueprint package · DOI 10.5281/zenodo.24181563
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Ion-Beam Shepherd for Contactless Removal of a Two-Tonne Derelict: Plume Momentum Budgets
This paper presents a computed design study of a civilian orbital-safety system based on contactless momentum transfer from an ion thruster plume impinging on the target. It is a computed study of a civilian orbital-safety system, with no targeting application and no weapon application.
Design paper · DOI 10.5281/zenodo.24182960 · Blueprint package · DOI 10.5281/zenodo.24183251
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Centrifugal Casting Rig Using Rotation for Mould Filling in Orbit: Rotational Energy, Artificial-Gravity and Thermal Budgets
This paper presents a computed design study, SIMULATED, NOT MEASURED, for cylindrical bushings, ring gears and axisymmetric housings in orbit, using molten aluminium-silicon alloy from a resistance melter. The operating principle is distinct from neighbouring production methods: a mould mounted at the rim of a 1.2 metre rotor is spun so that centrifugal acceleration, rather than gravity, drives molten metal outward and holds it against the mould wall while it freezes.
Design paper · DOI 10.5281/zenodo.24184964 · Blueprint package · DOI 10.5281/zenodo.24185658
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Friction-Stir Additive Machine for Orbital Fabrication of Large Aluminium Plates: Torque, Travel and Energy Budgets
This paper presents a computed design study, SIMULATED, NOT MEASURED, for large flat structural plates and tank wall sections too wide for powder beds in orbit, using aluminium 2219 plate feedstock and shoulder stock. The operating principle is distinct from neighbouring production methods: a rotating non-consumable tool plunges into stacked plate and traverses, plasticising and forging the metal in the solid state as it goes, so a large plate is built by stirring rather than melting.
Design paper · DOI 10.5281/zenodo.24185036 · Blueprint package · DOI 10.5281/zenodo.24185712
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Electron-Beam Melting Printer for Orbital Production of Titanium Components: Energy, Thermal and Mass Budgets
This paper presents a computed design study, SIMULATED, NOT MEASURED, for titanium brackets, fittings and pressure housings in orbit, using Ti-6Al-4V powder, 45-106 micrometre grade. The operating principle is distinct from neighbouring production methods: a focused electron beam, accelerated through 60 kilovolts and magnetically deflected, scans a preheated powder bed in vacuum and fully melts each layer.
Design paper · DOI 10.5281/zenodo.24185026 · Blueprint package · DOI 10.5281/zenodo.24185706
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Inchworm Robotic Assembler for Orbital Construction of a 100-Metre Truss: Joint Energy, Traverse and Schedule Budgets
This paper presents a computed design study, SIMULATED, NOT MEASURED, for a 100 metre backbone truss for antennas, radiators and solar arrays in orbit, using pre-manufactured carbon-composite struts and node fittings launched as a kit. The operating principle is distinct from neighbouring production methods: a two-ended inchworm robot walks along the truss it is building, alternately gripping with each end, placing struts from a carried magazine and driving each joint home, so the structure itself is the robot's railway and no free-flying translation is needed for most operations.
Design paper · DOI 10.5281/zenodo.24185059 · Blueprint package · DOI 10.5281/zenodo.24185716
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Orbital Electroforming System for Nickel Reflector Shells and Waveguides: Faraday-Law, Power and Solution-Mass Budgets
This paper presents a computed design study, SIMULATED, NOT MEASURED, for thin nickel reflector shells, waveguide sections and precision replication moulds in orbit, using nickel sulfamate electrolyte and soluble nickel anodes. The operating principle is distinct from neighbouring production methods: nickel ions are reduced onto a rotating mandrel from a temperature-controlled sulfamate bath, building a stress-free shell atom by atom at a rate fixed by Faraday's law.
Design paper · DOI 10.5281/zenodo.24185006 · Blueprint package · DOI 10.5281/zenodo.24185685
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Buried Regolith Sensible-Heat Store Carrying Habitat Heat Through the Lunar Night
This study sizes a buried regolith sensible-heat store that carries a 354-hour lunar night heating load of 10 kilowatts: allowing for losses, the store must hold 4.4 megawatt-hours of heat, requiring 99.6 tonnes of regolith swung through 200 kelvin, a volume of 66 cubic metres equivalent to a cube 4.0 metres on a side. Sizing follows from computed thermal budgets derived in the study.
Design paper · DOI 10.5281/zenodo.24189169 · Blueprint package · DOI 10.5281/zenodo.24190292
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Loop Heat Pipe Radiator Array Rejecting Habitat Waste Heat Across the Day-Night Cycle
This study sizes a loop heat pipe radiator array rejecting 50.0 kilowatts of habitat waste heat from panels at 310 kelvin: each square metre radiates 482 watts, so the array needs 104 square metres before margin and 130 square metres with the stated design margin, served by 34 transport loops at the stated per-loop capacity. Sizing follows from computed thermal budgets derived in the study.
Design paper · DOI 10.5281/zenodo.24189062 · Blueprint package · DOI 10.5281/zenodo.24190235
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Water-Ice Phase-Change Buffer Smoothing Peak Thermal Loads at a Lunar Habitat
This study sizes a water-ice phase-change buffer that shaves an 8 kilowatt thermal peak lasting 6 hours: the buffer must absorb 173 megajoules, requiring 0.52 tonnes of ice with a volume of 0.57 cubic metres at the stated utilisation. Sizing follows from computed thermal budgets derived in the study.
Design paper · DOI 10.5281/zenodo.24189251 · Blueprint package · DOI 10.5281/zenodo.24190370
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Electrostatic Precipitator Airlock Stage for Suit and Equipment Dust Removal
This study sizes an electrostatic precipitator stage for a habitat airlock: at the stated migration velocity, plate area and flow, collection efficiency is 99.33 percent, reducing a stated 50 gram incoming dust load per entry to a residual of 0.337 grams. Sizing follows from computed budgets derived in the study.
Design paper · DOI 10.5281/zenodo.24188952 · Blueprint package · DOI 10.5281/zenodo.24190207
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Inflatable Formwork with a Regolith-Covered Arch for Rapid Habitat Shielding Construction
This study sizes inflatable-formwork construction of a regolith-covered arch bay of 8 metre span and 12 metre length: the arch presents 151 square metres, a 1 metre cover requires 151 cubic metres, about 226 tonnes, of regolith, and the cover weight load of 2430 pascals under lunar gravity sits within the stated form pressure during placement. Sizing follows from computed regolith budgets derived in the study.
Design paper · DOI 10.5281/zenodo.24189024 · Blueprint package · DOI 10.5281/zenodo.24190221
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Microwave-Sintered Regolith Bricks Assembled into a Shielding Vault
This study sizes microwave-sintered regolith brick production for a hemispherical shielding vault of 4 metre radius: each brick needs 18.3 megajoules at the stated coupling efficiency, the vault needs 1257 bricks, and total production energy is 23.0 gigajoules, about 128 hours at 50 kilowatts of microwave power. Brick mass is 12.0 kilograms.
Design paper · DOI 10.5281/zenodo.24189082 · Blueprint package · DOI 10.5281/zenodo.24190243
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Passive Radiative Cooling Panels for Lunar Daytime Equipment Temperature Control
This study sizes passive radiative cooling panels operating in lunar daylight: a panel at 300 kelvin emits 436 watts per square metre, absorbs 109 watts of sunlight at the stated absorptance, and after a stated regolith infrared load delivers a net cooling flux of 267 watts per square metre, so a 10 kilowatt cooling duty needs 37 square metres. Sizing follows from computed thermal budgets derived in the study.
Design paper · DOI 10.5281/zenodo.24189133 · Blueprint package · DOI 10.5281/zenodo.24190260
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Regolith Berm Shielding for a Surface Habitat Sized Against Solar Particle Events and Galactic Cosmic Rays
This study sizes regolith berm shielding for a reference surface habitat: an areal density of 36 grams per square centimetre, a thickness of 0.24 metres at the stated bulk density, reduces a solar particle event dose proxy by a factor of 20, while the same berm reduces a galactic cosmic ray dose proxy by only a factor of 2.22. Covering 245 square metres requires 59 cubic metres, about 88 tonnes, of regolith.
Design paper · DOI 10.5281/zenodo.24189157 · Blueprint package · DOI 10.5281/zenodo.24190279
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Capillary Heat-Pipe Network for Moving Waste Heat on a Mars Base: Two-Phase Transport Sizing
This paper presents a sized design for a Mars surface system based on capillary-driven two-phase heat-pipe transport using a wick and a working fluid. A network of water and ammonia heat pipes linking heat sources inside a habitat to external radiators.
Design paper · DOI 10.5281/zenodo.24193537 · Blueprint package · DOI 10.5281/zenodo.24194303
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Regolith Berm Shield for a Mars Habitat: Mass-Attenuation Sizing Against Galactic Cosmic Rays and Solar Particle Events
This paper presents a sized design for a Mars surface system based on passive mass attenuation of radiation in a thick layer of Martian regolith placed over and around a habitat. An excavated-regolith berm and roof layer shielding an inflatable or rigid habitat module.
Design paper · DOI 10.5281/zenodo.24193609 · Blueprint package · DOI 10.5281/zenodo.24194352
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Water-Wall Shield for a Mars Habitat: Hydrogenous Attenuation with a Dual-Use Resource
This paper presents a sized design for a Mars surface system based on attenuation in hydrogen-rich water, which is efficient per unit mass against protons and secondary neutrons. Panels and tanks of stored water arranged as the walls of a crew refuge and sleeping quarters.
Design paper · DOI 10.5281/zenodo.24193812 · Blueprint package · DOI 10.5281/zenodo.24194445
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Active Magnetic Shield for a Mars Crew Refuge: Charged-Particle Deflection Sizing
This paper presents a sized design for a Mars surface system based on deflection of charged particles by the Lorentz force in a superconducting magnetic field, rather than absorption in mass. A superconducting coil system around a small crew refuge that bends incoming charged particles away from the refuge volume.
Design paper · DOI 10.5281/zenodo.24193574 · Blueprint package · DOI 10.5281/zenodo.24194315
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Carbon-Dioxide Snow Cleaning for Mars Radiators and Sensors: Subliming-Jet Dust Removal Sizing
This paper presents a sized design for a Mars surface system based on cleaning by a jet of carbon-dioxide snow that lifts particles and then sublimes away, leaving no liquid residue. A robotic cleaning head using compressed Martian carbon dioxide expanded into snow particles.
Design paper · DOI 10.5281/zenodo.24193425 · Blueprint package · DOI 10.5281/zenodo.24194272
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Sky-Facing Radiator Panels for Waste-Heat Rejection on Mars: Radiative Sizing Against a Cold Sky
This paper presents a sized design for a Mars surface system based on thermal radiation from high-emissivity panels to the cold Martian sky and space. Deployable radiator panels that reject habitat and power-system waste heat by radiation alone, without expending water.
Design paper · DOI 10.5281/zenodo.24193638 · Blueprint package · DOI 10.5281/zenodo.24194378
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Ceramic Regolith Brick Kiln with Ambient-Heat Assist for Venus Construction: Batch Energy Sizing
This study sizes a Ceramic Regolith Brick Kiln with Ambient-Heat Assist for Venus Construction for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted.
Design paper · DOI 10.5281/zenodo.24199639 · Blueprint package · DOI 10.5281/zenodo.24200276
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Pressure-Equalised Construction Crane for Venus Surface Materials Handling: Lift and Wind-Load Sizing
This study sizes a Pressure-Equalised Construction Crane for Venus Surface Materials Handling for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted.
Design paper · DOI 10.5281/zenodo.24199800 · Blueprint package · DOI 10.5281/zenodo.24200202
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Seismic Station with Passive Thermal Control for the Venus Surface: Time Constant and Power Sizing
This study sizes a Seismic Station with Passive Thermal Control for the Venus Surface for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted.
Design paper · DOI 10.5281/zenodo.24199740 · Blueprint package · DOI 10.5281/zenodo.24200285
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Silicon-Carbide Electronics Enclosure with Heat-Pipe Cooling to a Raised Radiator on Venus: Thermal Sizing
This study sizes a Silicon-Carbide Electronics Enclosure with Heat-Pipe Cooling to a Raised Radiator on Venus for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted.
Design paper · DOI 10.5281/zenodo.24199816 · Blueprint package · DOI 10.5281/zenodo.24200301
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Spherical Pressure-Vessel Habitat Module for the Venus Surface: Shell and Buckling Sizing
This study sizes a Spherical Pressure-Vessel Habitat Module for the Venus Surface for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted.
Design paper · DOI 10.5281/zenodo.24199504 · Blueprint package · DOI 10.5281/zenodo.24200312
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Sulphuric-Acid-Resistant Heat Exchanger for Venus Surface Plant: Duty and Surface Sizing
This study sizes a Sulphuric-Acid-Resistant Heat Exchanger for Venus Surface Plant for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted.
Design paper · DOI 10.5281/zenodo.24199525 · Blueprint package · DOI 10.5281/zenodo.24200133
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Surface-Linked Hot-Gas Balloon Station for the Venus Deep Atmosphere: Buoyancy and Tether Sizing
This study sizes a Surface-Linked Hot-Gas Balloon Station for the Venus Deep Atmosphere for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted.
Design paper · DOI 10.5281/zenodo.24199557 · Blueprint package · DOI 10.5281/zenodo.24200211
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Aerobot for Long-Duration Venus Balloon Flight: Power and Thermal Sizing Across Altitude
This study sizes an Aerobot for Long-Duration Venus Balloon Flight for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted.
Design paper · DOI 10.5281/zenodo.24199780 · Blueprint package · DOI 10.5281/zenodo.24200147
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Buried Fission Power Vault for a Lunar Settlement: Shielding Depth, Heat Rejection and Safety Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is a small civilian fission reactor emplaced in an excavated vault and covered with regolith, so earth shielding replaces a heavy manufactured shadow shield and distance plus burial protect the crew.
Design paper · DOI 10.5281/zenodo.24210993 · Blueprint package · DOI 10.5281/zenodo.24211366
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Buried Greenhouse on Mars with a Regolith Roof: Light Transmission, Heating and Growing Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is a greenhouse sunk into Martian ground with light delivered through surface collectors and fibre guides, supplemented by electric lighting, so crops gain shielding without losing all natural light.
Design paper · DOI 10.5281/zenodo.24211003 · Blueprint package · DOI 10.5281/zenodo.24211368
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Buried Water Storage Vault for a Lunar Base: Tank Sizing, Freeze Protection and Shielding Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is water stored in buried tanks where regolith cover holds temperatures steady, prevents freezing without continuous heating and shields the reserve from radiation and impacts.
Design paper · DOI 10.5281/zenodo.24211011 · Blueprint package · DOI 10.5281/zenodo.24211384
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Cable-Net Roof for a Wide Underground Cavern on Mars: Tension Structure, Span and Excavation Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is a tensioned cable net anchored into cavern walls, carrying a regolith shielding layer over a wide clear span that no masonry arch of reasonable thickness could cover.
Design paper · DOI 10.5281/zenodo.24211024 · Blueprint package · DOI 10.5281/zenodo.24211398
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Closed-Loop Geothermal Power Plant for a Subsurface Mars Base: Heat Flow, Well Depth and Output Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is closed-loop borehole heat exchangers circulating a working fluid through hot rock at depth, converting the planetary geothermal gradient into electricity with a binary-cycle turbine.
Design paper · DOI 10.5281/zenodo.24211048 · Blueprint package · DOI 10.5281/zenodo.24211414
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Cut-and-Cover Trench Habitat on the Moon: Excavation Volumes, Berm Shielding and Thermal Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is habitat modules placed in an open excavation and then covered with the excavated regolith, the simplest construction sequence in which the spoil heap becomes the shielding.
Design paper · DOI 10.5281/zenodo.24211034 · Blueprint package · DOI 10.5281/zenodo.24211403
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Drilled Borehole Habitat on Mars: Shaft Stability, Shielding and Power Budgets for a Vertical Outpost
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is a vertical drilled shaft lined with stacked cylindrical modules, so depth itself supplies shielding and the small shaft diameter keeps wall stresses low.
Design paper · DOI 10.5281/zenodo.24210985 · Blueprint package · DOI 10.5281/zenodo.24211360
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Greenhouse Inside a Lunar Lava Tube: Lighting Power, Thermal Control and Growing Area Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is crop production inside a shielded lava tube under electric lighting, where the tube removes radiation and micrometeorite risk and the lighting load doubles as the heating source.
Design paper · DOI 10.5281/zenodo.24211123 · Blueprint package · DOI 10.5281/zenodo.24211454
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Melt-Tunnel Habitat in Martian Ice-Rich Ground: Melting Energy, Cavern Stability and Thermal Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is a heated probe melting a horizontal cavern directly inside a subsurface ice layer, forming smooth ice walls that are then lined, so excavation and water production happen in the same operation.
Design paper · DOI 10.5281/zenodo.24211136 · Blueprint package · DOI 10.5281/zenodo.24211472
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Pressure Shell Inside a Lunar Lava Tube: Roof Load, Shielding Depth and Thermal Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is an inflatable pressure liner anchored inside a natural lava tube, so the rock itself carries the overburden and provides the shielding while the liner carries only the pressure difference.
Design paper · DOI 10.5281/zenodo.24210968 · Blueprint package · DOI 10.5281/zenodo.24211464
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Regolith Thermal Battery for a Mars Habitat: Charge Cycles, Storage Capacity and Insulation Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is electrical energy converted to heat and stored in a buried insulated regolith mass during power-rich periods, then recovered as habitat heating, trading conversion losses for very cheap storage mass.
Design paper · DOI 10.5281/zenodo.24211169 · Blueprint package · DOI 10.5281/zenodo.24211498
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Sintered Regolith Arch Roof over a Lunar Trench Habitat: Span, Shielding and Construction Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is a sintered regolith arch built in place over an excavated trench, working purely in compression so that local material provides both structure and radiation shielding.
Design paper · DOI 10.5281/zenodo.24211155 · Blueprint package · DOI 10.5281/zenodo.24211484
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Thermal System for an Underground Water-Ice Mine on Mars: Extraction Energy, Melt Rates and Power Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is controlled thermal extraction of water from ice-rich ground in a sealed subsurface gallery, heating only the working face so the surrounding frozen ground stays stable.
Design paper · DOI 10.5281/zenodo.24211084 · Blueprint package · DOI 10.5281/zenodo.24211439
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Ice-Shielded Subsurface Module at the Lunar Poles: Water Overburden, Thermal Balance and Power Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is a habitat module buried under a layer of water ice, so the shielding material is also a stored resource and its phase-change behaviour buffers temperature swings.
Design paper · DOI 10.5281/zenodo.24211096 · Blueprint package · DOI 10.5281/zenodo.24211446
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
An Underground Construction Depot and Workshop for a Lunar Settlement: Cavern, Power and Excavation Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is a mined underground hall housing the settlement's workshop and construction plant, where burial protects machinery from radiation, dust cycling and temperature swings and extends its working life.
Design paper · DOI 10.5281/zenodo.24211206 · Blueprint package · DOI 10.5281/zenodo.24211509
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
Ground-Coupled Heat Rejection for a Subsurface Lunar Base: Borehole Radiators, Conductive Capacity and Area Budgets
This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is waste heat conducted away through arrays of fluid-filled boreholes into deep rock, using the ground itself as the heat sink instead of surface radiator panels.
Design paper · DOI 10.5281/zenodo.24211064 · Blueprint package · DOI 10.5281/zenodo.24211430
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Beamed-Microwave Sail Probe: Diffraction Limits, Boost Distance and Cruise Budgets
This study sizes an interstellar cruise system from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is a beamed-microwave sail: a phased transmitter array pushes a large lightweight mesh sail by photon pressure at microwave wavelengths, where transmitters are efficient and cheap per watt, but where diffraction spreads the beam far faster than at optical wavelengths.
Design paper · DOI 10.5281/zenodo.24213376 · Blueprint package · DOI 10.5281/zenodo.24213579
Licence this design Single-field or full licence · Terms on inquiry
Housing & Shelter
A Laser-Pushed Lightsail Flyby Probe: Beam Power, Sail Temperature and Cruise Budgets
This study sizes an interstellar cruise system from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is a ground- and orbit-based laser array illuminating a highly reflective sail for a single boost phase, after which the sailcraft coasts ballistically to its target with no onboard propulsion at all.
Design paper · DOI 10.5281/zenodo.24213221 · Blueprint package · DOI 10.5281/zenodo.24213532
Licence this design Single-field or full licence · Terms on inquiry